BEYOND ALL

X-ray
lmaging Solutions.

  • Products
  • Portable X-ray Unit

Portable X-ray Unit

[ Portable X-ray Unit ]

DIG-Series

  • High frequency inverter technology.
    Field Application : Indoor and Outdoor Radiography, Military use, Homecare, Emergency Security, Veterinary use etc.
  • Exclusive Rmeote control Function , allows the total control technical values by hand switch without placing your unit on the ground.
  • SID Measurement tape : BUilt-in measuring tape for SID is equipped for your convenience.
  • Display Reverse Switch, makes easy reading of digits fromopposite site.
  • Anatomical memory mode.
Model DIG-360 DIG-1100
Maximun output 20mA/100kV 35mA/100kV 60mA/100kV 100mA/110kV
Power rating 1.6kW 2.4kW 3.2kW 5.0kW
Frequency 70kHz 70kHz 50kHz 50kHz
kVp selection 40~100kV(1kV step) 40~100kV(1kV step) 40~100kV(1kV step) 40-110kV, 1kV steps
mA Selection - - - 20-100mA, Valiable
mA Selection 0.3~50mAs (22 steps) 0.4~100mAs (25 steps) 0.4~100mAs (25 steps) 0.1~100mAs, 38 setps
Focal spot 1.2mm 1.2mm 2.0mm 1.8mm
Anatomical program memory 4 selection 6 selection 8 selection Max 750 selection
Line Nominal 110V or 220V, 50Hz or 60Hz 110V or 220V, 50Hz or 60Hz 110V or 220V, 50Hz or 60Hz 220V(200-264VAC), 50Hz or 60Hz
Dimension 350Lx157Wx170H(mm) 350Lx250Wx206H(mm) 350Lx250Wx206H(mm) 429.3Lx240.5Wx218.5H(mm)
Weight 9.8kG 12.5kg 13kg 19.6kg
AirRay-20

[ Portable X-ray Unit ]

AirRay-20

  • Ultra-compact design 4.8kg
  • Fast charging in under 4 hours
  • Operate on internal battery
  • Clear Diagnostic Images
  • High frequency type X-ray generator
  • Maximum output: 90kV/20mA
  • 10 APR memory settings
  • Built-in LED collimator
  • Power requirements: 3.7VDC/5.3Ah
  • Built-in Ultra Capacitor
  • QC2.0, QC3.0 charge applicable (optional)
ContentsSpecification
Input PowerWired Charging5 VDC, 2A
Wireless Charging5 VDC, 1A
Output PowerMax. Output1.6kW
Max. kV / mA90kV / 20mA
Tube Voltage Range [kV]50 ~ 90kV in 1kV steps
mAs Range [mAs]0.4 ~ 20 mAs in 25 steps
0.4, 0.6, 0.8, 1.0, 1.25, 1.4, 1.6, 1.8, 2.0, 2.2, 2.5,
2.9, 3.2, 3.6, 4.0, 4.5, 5.0, 6.3, 8.0, 9.0, 10, 12.5, 16,
18, 20
Tube current [mA]20mA (50 ~ 80kV / 0.4 ~ 3.2mAs)
10mA (50 ~ 70kV / 3.6 ~ 20mAs)
10mA (71 ~ 80kV / 3.6 ~ 16mAs)
15mA (81 ~ 90kV / 0.4 ~ 3.2mAs)
8mA (81 ~ 90kV / 3.6 ~ 16mAs)
APR10 Memories
Max. DeviationkV±7%
mAs±(7% + 0.2 mAs)
IndicationkV / mAs : 7-Segment LED, LCD Display
X-ray TubeModel nameOX/70-1.0 (C.E.I.)
Focal Spot Size1.0mm
Target Angle16 degree
Inherent Filtration0.5mmAl
Anode Heat Content7kJ
CollimatorTypeDouble slit type, Manually operation
Min. X-ray Field Size≤ 5×5cm @ 100cm SID
Max. X-ray Field Size≤ 47×47cm @ 100cm SID
Timer5~30 sec (5 sec step)
Lamp3.3V LED Lamp
Laser (optional)Dual Laser
Dimension325 X 268 X 250
Weight5.3kg
BatteryLithium Polymer 3.7V 5300mAh
AirRay-mini

[ Portable X-ray Unit ]

AirRay-mini

  • Ultra-compact design 3.2kg
  • Operate on internal battery
  • Clear Diagnostic Images
  • High frequency type X-ray generator
  • Compact, lightweight with reliable power
  • Automatic SID
  • Adjustable collimator
  • Touch screen interface
  • Display TFT-LCD witch C-Touch (3.5 Inch, 800*480)
ItemsSpecifications
Input PowerAC Input100V-240 V~, 50/60 Hz, 1.8 A
Adaptor Output25.2 V
2 A
Battery22.2 V 2,200 mAh
Tube typeOX80-0.8
Maximum Output Power500 W
(50 kV, 10 mA)
Loading factor for Leakage radiation450 W (90 kV, 5 mA)
10 mAs
Generator TypeInverter
Frequency40kHz
Tube Voltage range50 ~ 90 kV
Tube Current range5 - 10 mA
mAs range0.2 mAs – 10 mAs, 18 Step
Max. TolerancekV± 7 %
mAs± (7 % + 0.2 mAs)
DisplayTFT-LCD witch C-Touch
(3.5 Inch, 800*480)
X-ray TubeInherent Filtration0.5 mm Al Eq.
Target Angle16°
Focus0.8 mm
Adjustable CollimatorTypeDouble slit type, Manually operation
X-ray Field SizeMAX 46×46 cm @ 100 cm SID
Timer20/30 sec selection
Lamp3.3 V LED Lamp
Size249x194x194 mm
Weight3.2 kg (Main body + Built-in Battery)