X-ray
lmaging Solutions.






| Model | DIG-360 | DIG-1100 | ||
|---|---|---|---|---|
| Maximun output | 20mA/100kV | 35mA/100kV | 60mA/100kV | 100mA/110kV |
| Power rating | 1.6kW | 2.4kW | 3.2kW | 5.0kW |
| Frequency | 70kHz | 70kHz | 50kHz | 50kHz |
| kVp selection | 40~100kV(1kV step) | 40~100kV(1kV step) | 40~100kV(1kV step) | 40-110kV, 1kV steps |
| mA Selection | - | - | - | 20-100mA, Valiable |
| mA Selection | 0.3~50mAs (22 steps) | 0.4~100mAs (25 steps) | 0.4~100mAs (25 steps) | 0.1~100mAs, 38 setps |
| Focal spot | 1.2mm | 1.2mm | 2.0mm | 1.8mm |
| Anatomical program memory | 4 selection | 6 selection | 8 selection | Max 750 selection |
| Line Nominal | 110V or 220V, 50Hz or 60Hz | 110V or 220V, 50Hz or 60Hz | 110V or 220V, 50Hz or 60Hz | 220V(200-264VAC), 50Hz or 60Hz |
| Dimension | 350Lx157Wx170H(mm) | 350Lx250Wx206H(mm) | 350Lx250Wx206H(mm) | 429.3Lx240.5Wx218.5H(mm) |
| Weight | 9.8kG | 12.5kg | 13kg | 19.6kg |
| Contents | Specification | |
|---|---|---|
| Input Power | Wired Charging | 5 VDC, 2A |
| Wireless Charging | 5 VDC, 1A | |
| Output Power | Max. Output | 1.6kW |
| Max. kV / mA | 90kV / 20mA | |
| Tube Voltage Range [kV] | 50 ~ 90kV in 1kV steps | |
| mAs Range [mAs] | 0.4 ~ 20 mAs in 25 steps 0.4, 0.6, 0.8, 1.0, 1.25, 1.4, 1.6, 1.8, 2.0, 2.2, 2.5, 2.9, 3.2, 3.6, 4.0, 4.5, 5.0, 6.3, 8.0, 9.0, 10, 12.5, 16, 18, 20 | |
| Tube current [mA] | 20mA (50 ~ 80kV / 0.4 ~ 3.2mAs) 10mA (50 ~ 70kV / 3.6 ~ 20mAs) 10mA (71 ~ 80kV / 3.6 ~ 16mAs) 15mA (81 ~ 90kV / 0.4 ~ 3.2mAs) 8mA (81 ~ 90kV / 3.6 ~ 16mAs) | |
| APR | 10 Memories | |
| Max. Deviation | kV | ±7% |
| mAs | ±(7% + 0.2 mAs) | |
| Indication | kV / mAs : 7-Segment LED, LCD Display | |
| X-ray Tube | Model name | OX/70-1.0 (C.E.I.) |
| Focal Spot Size | 1.0mm | |
| Target Angle | 16 degree | |
| Inherent Filtration | 0.5mmAl | |
| Anode Heat Content | 7kJ | |
| Collimator | Type | Double slit type, Manually operation |
| Min. X-ray Field Size | ≤ 5×5cm @ 100cm SID | |
| Max. X-ray Field Size | ≤ 47×47cm @ 100cm SID | |
| Timer | 5~30 sec (5 sec step) | |
| Lamp | 3.3V LED Lamp | |
| Laser (optional) | Dual Laser | |
| Dimension | 325 X 268 X 250 | |
| Weight | 5.3kg | |
| Battery | Lithium Polymer 3.7V 5300mAh | |
| Items | Specifications | |
|---|---|---|
| Input Power | AC Input | 100V-240 V~, 50/60 Hz, 1.8 A |
| Adaptor Output | 25.2 V 2 A | |
| Battery | 22.2 V 2,200 mAh | |
| Tube type | OX80-0.8 | |
| Maximum Output Power | 500 W (50 kV, 10 mA) | |
| Loading factor for Leakage radiation | 450 W (90 kV, 5 mA) 10 mAs | |
| Generator Type | Inverter | |
| Frequency | 40kHz | |
| Tube Voltage range | 50 ~ 90 kV | |
| Tube Current range | 5 - 10 mA | |
| mAs range | 0.2 mAs – 10 mAs, 18 Step | |
| Max. Tolerance | kV | ± 7 % |
| mAs | ± (7 % + 0.2 mAs) | |
| Display | TFT-LCD witch C-Touch (3.5 Inch, 800*480) | |
| X-ray Tube | Inherent Filtration | 0.5 mm Al Eq. |
| Target Angle | 16° | |
| Focus | 0.8 mm | |
| Adjustable Collimator | Type | Double slit type, Manually operation |
| X-ray Field Size | MAX 46×46 cm @ 100 cm SID | |
| Timer | 20/30 sec selection | |
| Lamp | 3.3 V LED Lamp | |
| Size | 249x194x194 mm | |
| Weight | 3.2 kg (Main body + Built-in Battery) | |